HPLC Method for Analysis of Hydroxyproline, Creatine, and Creatinine on Newcrom AH Column

HPLC Method for Analysis of Hydroxyproline, Creatine, Creatinine on Newcrom AH by SIELC Technologies

HPLC Method for Analysis of Hydroxyproline, Creatine, Creatinine on Newcrom AH Column by SIELC Technologies


 High Performance Liquid Chromatography (HPLC) Method for Analysis of Hydroxyproline, Creatine, Creatinine

Hydroxyproline is a non-essential amino acid primarily found in collagen, the main structural protein in connective tissues such as skin, bones, and cartilage. It plays a crucial role in maintaining collagen stability and is often used as a biomarker for collagen turnover and connective tissue disorders. Creatine is a naturally occurring compound found in muscles and is used to produce energy during high-intensity exercise. It is synthesized in the body from amino acids and stored in muscles for quick energy release. Creatinine, on the other hand, is a waste product produced from the breakdown of creatine. It is filtered by the kidneys and excreted in urine. The measurement of creatinine levels in the blood and urine is commonly used to assess kidney function, as high levels may indicate impaired kidney function or other health issues.

Hydroxyproline, Creatine, and Creatinine can be analyzed and separated using a Newcrom AH mixed-mode stationary phase column. The analysis utilizes an isocratic method with a simple mobile phase consisting of water, acetonitrile (MeCN), and phosphoric acid as a buffer. Detection is carried out using UV.

ColumnNewcrom AH, 4.6 x 150 mm, 5 µm, 100 A
Mobile PhaseMeCN/H2O – 10/90%
BufferH3PO4 – 0.1%
Flow Rate1.0 ml/min
DetectionUV 200 nm, 210 nm
Sample1. 1.6 mg/mL, 2. 0.15 mg/mL, 3. 0.06 mg/mL
Injection volume2 µl
LOD*1. 331.0 ppb, 2. 13.2 ppb, 3. 6.7 ppb (UV 200 nm)
1. 760.4 ppb, 2. 48.3 ppb, 3. 9.1 ppb (UV 210 nm)
* LOD was determined for this combination of instrument, method, and analyte, and it can vary from one laboratory to another even when the same general type of analysis is being performed.

Class of Compounds
Amino Acid-Derived compounds
Analyzing CompoundsHydroxyproline, Creatine, Creatinine

Application Column

Newcrom AH

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A

Add to cart
Application Analytes:
Creatine
Creatinine
Hydroxyproline

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.