| CAS Number | 50-14-6 |
|---|---|
| Molecular Formula | C28H44O |
| Molecular Weight | 396.659 |
| InChI Key | MECHNRXZTMCUDQ-RKHKHRCZSA-N |
| LogP | 8.83 |
| Synonyms |
|
Applications:
Uv-Vis Spectrum of Ergocalciferol
March 16, 2026
Access the UV-Vis Spectrum SIELC Library

If you are looking for optimized HPLC method to analyze Ergocalciferol check our HPLC Applications library
For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can assist in selecting an appropriate wavelength for your analysis. Please note that certain mobile phases and buffers may block wavelengths below 230 nm, rendering absorbance measurement at these wavelengths ineffective. If detection below 230 nm is required, it is recommended to use acetonitrile and water as low UV-transparent mobile phases, with phosphoric acid and its salts, sulfuric acid, and TFA as buffers.
For some compounds, the UV-Vis Spectrum is affected by the pH of the mobile phase. The compound was dissolved in methanol.
HPLC Method For Analysis of Ergocalciferol (Vitamin D2) and Cholecalciferol (Vitamin D3) on Primesep SB Column
September 1, 2021
HPLC Method for Analysis of Ergocalciferol, Cholecalciferol on Primesep SB by SIELC Technologies

Ergocalciferol (Vitamin D2) and Cholecalciferol (Vitamin D3) are fat soluble vitamins that help your body absorb calcium and phosphorus. Your body can produce both when exposed to the sun, but you can also intake these essential vitamins through a daily multivitamin or a Vitamin D pill.
Vitamins D2 and D3 can be detected in the high UV regime. Using a Primesep SB reverse-phase column and a mobile phase consisting of water and acetonitrile with an acetic acid buffer, Vitamins D2 and D3 can be retained and separated. This analysis method can be UV detected at 265 nm.
| Column | Primesep SB, 4.6 x 150 mm, 5 µm, 100 A, dual ended |
| Mobile Phase | MeCN/H2O – 80/20% |
| Buffer | Acetic Acid – 0.1% |
| Flow Rate | 1.0 ml/min |
| Detection | UV 265 nm |
| Class of Compounds | Vitamin |
| Analyzing Compounds | Ergocalciferol, Cholecalciferol |
Application Column
Primesep SB
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended
Ergocalciferol
Separation of Ergocalciferol on Newcrom R1 HPLC column
February 16, 2018
Ergocalciferol can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.
Application Column
Newcrom R1
The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.
Select options