| CAS Number | 28911-01-5 |
|---|---|
| Molecular Formula | C17H12Cl2N4 |
| Molecular Weight | 343.210 |
| InChI Key | JOFWLTCLBGQGBO-UHFFFAOYSA-N |
| LogP | 2.42 |
| Synonyms |
|
Applications:
Uv-Vis Spectrum of Triazolam
February 16, 2026
Access the UV-Vis Spectrum SIELC Library

If you are looking for optimized HPLC method to analyze Triazolam check our HPLC Applications library
For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can assist in selecting an appropriate wavelength for your analysis. Please note that certain mobile phases and buffers may block wavelengths below 230 nm, rendering absorbance measurement at these wavelengths ineffective. If detection below 230 nm is required, it is recommended to use acetonitrile and water as low UV-transparent mobile phases, with phosphoric acid and its salts, sulfuric acid, and TFA as buffers.
For some compounds, the UV-Vis Spectrum is affected by the pH of the mobile phase. The spectra presented here are measured with an acidic mobile phase that has a pH of 3 or lower.
HPLC Method for Determination of Triazolam on Newcrom R1 Column
September 1, 2022
HPLC Method for Triazolam on Newcrom R1 by SIELC Technologies
High Performance Liquid Chromatography (HPLC) Method for Analysis of Triazolam.
Triazolam is a prescription-strength benzodiazepine with the chemical formula C17H12Cl2N4. It is used to treat insomnia, as it is a central nervous system depressant tranquilizer. Compared to other benzodiazepines, it is fairly obscure, preventing misuse and abuse of it. It is a Schedule IV drug.
Triazolam can be retained and analyzed on a Newcrom R1 reverse-phase column using a simple isocratic analytical method with a mobile phase consisting of Acetonitrile (MeCN), water, and Sulfuric acid as the ionic modifier. This analysis method can be UV detected at 200 nm with high resolution and peak symmetry.
| Column | Newcrom R1, 2.1 x 100 mm, 5 µm, 100 A, dual ended |
| Mobile Phase | MeCN – 35% |
| Buffer | H2SO4 – 0.2% |
| Flow Rate | 0.2 ml/min |
| Detection | UV 210 nm |
| Class of Compounds | Drug |
| Analyzing Compounds | Triazolam |
Application Column
Newcrom R1
Column Diameter: 2.1 mm
Column Length: 100 mm
Particle Size: 5 µm
Pore Size: 100 A
Column options: dual ended
Separation of Triazolam on Newcrom R1 HPLC column
February 16, 2018
Triazolam can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.
Application Column
Newcrom R1
The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.
Select options