2-(Dodecyloxy)ethyl sodium sulfate

2-(Dodecyloxy)ethyl sodium sulfate structural formula

CAS Number15826-16-1
Molecular FormulaC14H29NaO5S
Molecular Weight332.430
InChI KeyASEFUFIKYOCPIJ-UHFFFAOYSA-M
LogP3.36
Synonyms
  • 2-(Dodecyloxy)ethyl sodium sulfate
  • Sodium 2-(dodecyloxy)ethyl sulfate
  • Ethanol, 2-(dodecyloxy)-, hydrogen sulfate, sodium salt (1:1)
  • 15826-16-1
  • Ethanol, 2-(dodecyloxy)-, hydrogen sulfate, sodium salt
  • Sodium 2-(lauryloxy)ethyl sulfate
  • Ethanol, 2-(dodecyloxy)-, 1-(hydrogen sulfate), sodium salt (1:1)
  • Ethanol, 2-(dodecyloxy)-, sulfate, sodium sa
  • Ethylene glycol monododecyl ether sodium salt
  • Ethylene glycol monododecyl ether sulfate sodium salt
  • Ethylene glycol monolauryl ether sulfate sodium salt
  • SDES
  • sodium 2-(dodecyloxy)ethyl sulphate
  • Sulfate de sodium et de 2-(dodecyloxy)ethyle
  • Natrium 2-(dodecyloxy)ethylsulfat
  • sulfato de sodio y 2-(dodeciloxi)etilo
  • 2-(Dodecyloxy)ethanol, hydrogen sulfate sodium sal
  • Dodecyl sodium ethoxysulfate
  • 2-(Dodecyloxy)ethanol hydrogen sulfate sodium salt
  • EINECS 239-925-1
  • Sodium dodeceth-1 sulfate
  • Sodium 2-(dodecyloxy)ethyl sulfate
  • Sodium lauryl ethoxysulphate
  • Sodium lauryl oxyethyl sulfate

Applications:

Separation of 2-(Dodecyloxy)ethyl sodium sulfate on Newcrom R1 HPLC column

May 16, 2018
Separation of 2-(Dodecyloxy)ethyl sodium sulfate on Newcrom R1 HPLC column

2-(Dodecyloxy)ethyl sodium sulfate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
2-(Dodecyloxy)ethyl sodium sulfate
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.