Tag: Spectrum

Uv-Vis Spectrum of Ataciguat

Posted on July 16, 2026
Access the UV-Vis Spectrum SIELC Library If you are looking for optimized HPLC method to analyze check our HPLC Applications library UV/Vis.: λmax: 218, 293, 354 nm For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum...Read more

Uv-Vis Spectrum of Luminol

Posted on July 14, 2026
Access the UV-Vis Spectrum SIELC Library If you are looking for optimized HPLC method to analyze check our HPLC Applications library UV/Vis.: λmax: 218, 293, 354 nm For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum...Read more

Uv-Vis Spectrum of Tramadol

Posted on July 13, 2026
Access the UV-Vis Spectrum SIELC Library If you are looking for optimized HPLC method to analyze check our HPLC Applications library UV/Vis.: λmax: 220, 270 nm For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown...Read more

Uv-Vis Spectrum of Natamycin

Posted on July 13, 2026
Access the UV-Vis Spectrum SIELC Library If you are looking for optimized HPLC method to analyze check our HPLC Applications library UV/Vis.: λmax: 220, 293, 304, 320 nm For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV...Read more

Uv-Vis Spectrum of Lycopene

Posted on July 8, 2026
Access the UV-Vis Spectrum SIELC Library If you are looking for optimized HPLC method to analyze check our HPLC Applications library UV/Vis.: λmax: 284, 295, 346, 362, 446, 472, 502 nm For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being...Read more

Uv-Vis Spectrum of Imetit

Posted on June 9, 2026
Access the UV-Vis Spectrum SIELC Library If you are looking for optimized HPLC method to analyze check our HPLC Applications library UV/Vis.: λmax: 203 nm For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown can...Read more

Uv-Vis Spectrum of Vanilmandelic Acid

Posted on June 9, 2026
Access the UV-Vis Spectrum SIELC Library If you are looking for optimized HPLC method to analyze check our HPLC Applications library UV/Vis.: λmax: 222, 237, 280 nm For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum...Read more

Uv-Vis Spectrum of Blasticidin S

Posted on May 26, 2026
Access the UV-Vis Spectrum SIELC Library If you are looking for optimized HPLC method to analyze check our HPLC Applications library UV/Vis.: λmax: 196, 278 nm For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum shown...Read more

Uv-Vis Spectrum of 1-Benzylpiperidine-4-carbaldehyde

Posted on May 26, 2026
Access the UV-Vis Spectrum SIELC Library If you are looking for optimized HPLC method to analyze check our HPLC Applications library UV/Vis.: λmax: 190, 206, 262 nm For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum...Read more

Uv-Vis Spectrum of beta-Carotene

Posted on May 14, 2026
Access the UV-Vis Spectrum SIELC Library If you are looking for optimized HPLC method to analyze check our HPLC Applications library UV/Vis.: λmax: 275, 452, 478 nm For optimal results in HPLC analysis, it is recommended to measure absorbance at a wavelength that matches the absorption maximum of the compound(s) being analyzed. The UV spectrum...Read more