Separation of Propyl valerate on Newcrom R1 HPLC column
Posted on May 17, 2018
Propyl valerate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of 4,6-Dimethyl-2-benzopyrone on Newcrom R1 HPLC column
Posted on May 17, 2018
4,6-Dimethyl-2-benzopyrone can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of Benzene, 2-ethyl-1,3,5-trinitro- on Newcrom R1 HPLC column
Posted on May 17, 2018
Benzene, 2-ethyl-1,3,5-trinitro- can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of 4-Chloro-2-nitrobenzenesulphonamide on Newcrom R1 HPLC column
Posted on May 17, 2018
4-Chloro-2-nitrobenzenesulphonamide can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of Butyl isonicotinate on Newcrom R1 HPLC column
Posted on May 17, 2018
Butyl isonicotinate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of Azidamfenicol [INN:BAN:DCF] on Newcrom R1 HPLC column
Posted on May 17, 2018
Azidamfenicol [INN:BAN:DCF] can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of 1-(3-Methyl-2-thienyl)ethan-1-one on Newcrom R1 HPLC column
Posted on May 17, 2018
1-(3-Methyl-2-thienyl)ethan-1-one can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of 2-Methyl-2-propylpropane-1,3-diyl dinicotinate on Newcrom R1 HPLC column
Posted on May 17, 2018
2-Methyl-2-propylpropane-1,3-diyl dinicotinate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of 1-Nitro-2,2-bis(methylthio)ethylene on Newcrom R1 HPLC column
Posted on May 17, 2018
1-Nitro-2,2-bis(methylthio)ethylene can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of Methyl 6-methylpyridine-2-carboxylate on Newcrom R1 HPLC column
Posted on May 17, 2018
Methyl 6-methylpyridine-2-carboxylate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more