Separation of 3-(3-Butenyl)-2,4,4-trimethylcyclohex-2-en-1-one on Newcrom R1 HPLC column
Posted on May 17, 2018
3-(3-Butenyl)-2,4,4-trimethylcyclohex-2-en-1-one can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of ar,ar,ar-Trinitrobenzenetriamine on Newcrom R1 HPLC column
Posted on May 17, 2018
ar,ar,ar-Trinitrobenzenetriamine can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of Disulfamide on Newcrom R1 HPLC column
Posted on May 17, 2018
In the human body, disulfamide inhibits benzenedisulfonamide and carbonic anhydrase (CA). This causes diuresis as the inhibition of carbonic anhydrase prevents the reabsorption of water by the kidneys. Disulfamide can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS)...Read more
Separation of Pentyl 2-cyanoacrylate on Newcrom R1 HPLC column
Posted on May 17, 2018
Pentyl 2-cyanoacrylate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of 4,5-Diphenyl-4-oxazoline-2-thione on Newcrom R1 HPLC column
Posted on May 17, 2018
4,5-Diphenyl-4-oxazoline-2-thione can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of 7-Leucylamido-4-methylcoumarin on Newcrom R1 HPLC column
Posted on May 17, 2018
7-Leucylamido-4-methylcoumarin can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of 7-(N,N-Dimethylsulphamoyl)-2,3-dihydro-1,4-benzodioxin-5-carboxylic acid on Newcrom R1 HPLC column
Posted on May 17, 2018
7-(N,N-Dimethylsulphamoyl)-2,3-dihydro-1,4-benzodioxin-5-carboxylic acid can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of N-Allylcyclohexylamine on Newcrom R1 HPLC column
Posted on May 17, 2018
N-Allylcyclohexylamine can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of tert-Butyl phenyl carbonate on Newcrom R1 HPLC column
Posted on May 17, 2018
tert-Butyl phenyl carbonate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography...Read more
Separation of 10-Propionylphenothiazine on Newcrom R1 HPLC column
Posted on May 17, 2018
10-Propionylphenothiazine can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more