Separation of 9-(9H-Xanthen-9-ylidene)-9H-xanthene on Newcrom R1 HPLC column
Posted on May 16, 2018
9-(9H-Xanthen-9-ylidene)-9H-xanthene can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of Bis-(4-methylumbelliferyl)phosphate on Newcrom R1 HPLC column
Posted on May 16, 2018
Bis-(4-methylumbelliferyl)phosphate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of 3-Methyladenine on Newcrom R1 HPLC column
Posted on May 16, 2018
3-Methyladenine can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of (1S-(1alpha,2beta,5alpha))-5-(Isopropyl)-2-methylcyclohexyl acetate on Newcrom R1 HPLC column
Posted on May 16, 2018
(1S-(1alpha,2beta,5alpha))-5-(Isopropyl)-2-methylcyclohexyl acetate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of Ethanone, 2-bromo-1-tricyclo(3.3.1.1(sup 3,7))dec-1-yl- on Newcrom R1 HPLC column
Posted on May 16, 2018
Ethanone, 2-bromo-1-tricyclo(3.3.1.1(sup 3,7))dec-1-yl- can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography...Read more
Separation of Isopropyl 2-bromo-2-methylpropionate on Newcrom R1 HPLC column
Posted on May 16, 2018
Isopropyl 2-bromo-2-methylpropionate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of O-Methyl-3-phenyl-L-alanine hydrogen sulphate on Newcrom R1 HPLC column
Posted on May 16, 2018
O-Methyl-3-phenyl-L-alanine hydrogen sulphate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography...Read more
Separation of Bis(2-((2-methyl-1-oxoallyl)oxy)ethyl) dihydrogen benzene-1,2,4,5-tetracarboxylate on Newcrom R1 HPLC column
Posted on May 16, 2018
Bis(2-((2-methyl-1-oxoallyl)oxy)ethyl) dihydrogen benzene-1,2,4,5-tetracarboxylate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography...Read more
Separation of Diethylbromoacetamide on Newcrom R1 HPLC column
Posted on May 16, 2018
Diethylbromoacetamide can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of N-Ethyl-2-isopropyl-2,3-dimethylbutyramide on Newcrom R1 HPLC column
Posted on May 16, 2018
N-Ethyl-2-isopropyl-2,3-dimethylbutyramide can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more