Separation of 4,11-Diamino-2-(2-methylpropyl)-1H-naphth(2,3-f)isoindole-1,3,5,10(2H)-tetrone on Newcrom R1 HPLC column
Posted on May 16, 2018
4,11-Diamino-2-(2-methylpropyl)-1H-naphth(2,3-f)isoindole-1,3,5,10(2H)-tetrone can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of Methyl 5-formylvalerate on Newcrom R1 HPLC column
Posted on May 16, 2018
Methyl 5-formylvalerate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of 6,7-Dimethyl-2,3-di-2-pyridylquinoxaline on Newcrom R1 HPLC column
Posted on May 16, 2018
6,7-Dimethyl-2,3-di-2-pyridylquinoxaline can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of Butilfenin on Newcrom R1 HPLC column
Posted on May 16, 2018
Butilfenin can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of Propanamide, N-(4-chlorophenyl)-2,2-dimethyl- on Newcrom R1 HPLC column
Posted on May 16, 2018
Propanamide, N-(4-chlorophenyl)-2,2-dimethyl- can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of p-Fluorobenzylamine hydrochloride on Newcrom R1 HPLC column
Posted on May 16, 2018
p-Fluorobenzylamine hydrochloride can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of Propyl-3-tert-butylphenoxyacetate on Newcrom R1 HPLC column
Posted on May 16, 2018
Propyl-3-tert-butylphenoxyacetate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of 4-Benzyloxyphenylacetic acid on Newcrom R1 HPLC column
Posted on May 16, 2018
4-Benzyloxyphenylacetic acid can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of 6-Chloro-2-nitrobenzonitrile on Newcrom R1 HPLC column
Posted on May 16, 2018
6-Chloro-2-nitrobenzonitrile can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of 2,4,6,8-Tetranitro-2,4,6,8-tetraazanonane-1,9-diyl diacetate on Newcrom R1 HPLC column
Posted on May 16, 2018
2,4,6,8-Tetranitro-2,4,6,8-tetraazanonane-1,9-diyl diacetate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more