Separation of N-(3-Allyl-4-hydroxyphenyl)acetamide on Newcrom R1 HPLC column

Posted on May 16, 2018
Tags: simulated
N-(3-Allyl-4-hydroxyphenyl)acetamide can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more

Separation of 4-(4-Chlorophenyl)-N,N-dimethyl-1-(p-tolylsulphonyl)piperidine-4-carboxamide on Newcrom R1 HPLC column

Posted on May 16, 2018
Tags: simulated
4-(4-Chlorophenyl)-N,N-dimethyl-1-(p-tolylsulphonyl)piperidine-4-carboxamide can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more

Separation of N-Ethyl-6-methylpyridine-3-ethylamine on Newcrom R1 HPLC column

Posted on May 16, 2018
Tags: simulated
N-Ethyl-6-methylpyridine-3-ethylamine can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more

Separation of Ethyl 4-cyano-4-(phenylamino)piperidine-1-carboxylate on Newcrom R1 HPLC column

Posted on May 16, 2018
Tags: simulated
Ethyl 4-cyano-4-(phenylamino)piperidine-1-carboxylate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more

Separation of Ethyl cis-4-amino-3-hydroxypiperidine-1-carboxylate on Newcrom R1 HPLC column

Posted on May 16, 2018
Tags: simulated
Ethyl cis-4-amino-3-hydroxypiperidine-1-carboxylate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more

Separation of N-(4-(N-Hexadecyl-N-methylsulphamoyl)-2,5-dimethoxyphenyl)-3-(p-methoxyphenyl)-3-oxopropionamide on Newcrom R1 HPLC column

Posted on May 16, 2018
Tags: simulated
N-(4-(N-Hexadecyl-N-methylsulphamoyl)-2,5-dimethoxyphenyl)-3-(p-methoxyphenyl)-3-oxopropionamide can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more

Separation of Norcyclizine on Newcrom R1 HPLC column

Posted on May 16, 2018
Tags: simulated
Norcyclizine can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more

Separation of 4-Chloro-3-oxo-N-(o-tolyl)butyramide on Newcrom R1 HPLC column

Posted on May 16, 2018
Tags: simulated
4-Chloro-3-oxo-N-(o-tolyl)butyramide can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more

Separation of 4-Allyl-1-butoxy-2-methoxybenzene on Newcrom R1 HPLC column

Posted on May 16, 2018
Tags: simulated
4-Allyl-1-butoxy-2-methoxybenzene can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more

Separation of 2-Hydroxy-11H-benzo(a)carbazole-3-carboxylic acid on Newcrom R1 HPLC column

Posted on May 16, 2018
Tags: simulated
2-Hydroxy-11H-benzo(a)carbazole-3-carboxylic acid can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more