Separation of 2-(tert-Butyl)-6-methylnaphthalene on Newcrom R1 HPLC column
Posted on May 17, 2018
2-(tert-Butyl)-6-methylnaphthalene can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of 2-((4-Amino-3-bromo-9,10-dihydro-9,10-dioxo-1-anthryl)amino)benzoic acid on Newcrom R1 HPLC column
Posted on May 17, 2018
2-((4-Amino-3-bromo-9,10-dihydro-9,10-dioxo-1-anthryl)amino)benzoic acid can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of 1,3-Bis(1,1-dimethylethyl)-2-naphthol on Newcrom R1 HPLC column
Posted on May 17, 2018
1,3-Bis(1,1-dimethylethyl)-2-naphthol can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of Ethyl ((4-phenyl-1-(phenylmethyl)-4-piperidyl)methyl)carbamate on Newcrom R1 HPLC column
Posted on May 17, 2018
Ethyl ((4-phenyl-1-(phenylmethyl)-4-piperidyl)methyl)carbamate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of 1-((4-(m-Tolyl)-4-piperidyl)carbonyl)pyrrolidine on Newcrom R1 HPLC column
Posted on May 17, 2018
1-((4-(m-Tolyl)-4-piperidyl)carbonyl)pyrrolidine can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of 2-(2-Bromophenyl)-5-phenyl-1,3,4-oxadiazole on Newcrom R1 HPLC column
Posted on May 17, 2018
2-(2-Bromophenyl)-5-phenyl-1,3,4-oxadiazole can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of N-Piperidin-4-ylbenzene-1,2-diamine on Newcrom R1 HPLC column
Posted on May 17, 2018
N-Piperidin-4-ylbenzene-1,2-diamine can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of 2’-Chloroethyl 3-amino-4-methylbenzoate on Newcrom R1 HPLC column
Posted on May 17, 2018
2’-Chloroethyl 3-amino-4-methylbenzoate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of Benzyl p-tolyl ether on Newcrom R1 HPLC column
Posted on May 17, 2018
Benzyl p-tolyl ether can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography...Read more
Separation of Cyclotridecanone on Newcrom R1 HPLC column
Posted on May 17, 2018
Cyclotridecanone can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more