Separation of 4,6-Bis[2-(4-hydroxyphenyl)propan-2-yl]benzene-1,3-diol on Newcrom R1 HPLC column
Posted on May 16, 2018
4,6-Bis[2-(4-hydroxyphenyl)propan-2-yl]benzene-1,3-diol can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of 1-[2-Hydroxy-3-(prop-2-en-1-yl)phenyl]propan-1-one on Newcrom R1 HPLC column
Posted on May 16, 2018
1-[2-Hydroxy-3-(prop-2-en-1-yl)phenyl]propan-1-one can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of 2-(2,4-Dichlorophenyl)-1-(1H-1,2,4-triazol-1-yl)pent-4-en-2-ol on Newcrom R1 HPLC column
Posted on May 16, 2018
2-(2,4-Dichlorophenyl)-1-(1H-1,2,4-triazol-1-yl)pent-4-en-2-ol can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of 1,2,4,9-Tetrahydro-3H-carbazol-3-one on Newcrom R1 HPLC column
Posted on May 16, 2018
1,2,4,9-Tetrahydro-3H-carbazol-3-one can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of CHEMBL2311179 on Newcrom R1 HPLC column
Posted on May 16, 2018
CHEMBL2311179 can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of Ethyl 1-ethyl-6,7,8-trifluoro-4-oxo-1,4-dihydroquinoline-3-carboxylate on Newcrom R1 HPLC column
Posted on May 16, 2018
Ethyl 1-ethyl-6,7,8-trifluoro-4-oxo-1,4-dihydroquinoline-3-carboxylate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more
Separation of 6-Methoxy-N~2~-methylpyridine-2,3-diamine on Newcrom R1 HPLC column
Posted on May 16, 2018
6-Methoxy-N~2~-methylpyridine-2,3-diamine can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of Aminopropylvinylether on Newcrom R1 HPLC column
Posted on May 16, 2018
Aminopropylvinylether can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of N-(2,4-Dichloro-5-hydroxyphenyl)acetamide on Newcrom R1 HPLC column
Posted on May 16, 2018
N-(2,4-Dichloro-5-hydroxyphenyl)acetamide can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is...Read more
Separation of METHYL 2-(4-BROMOPHENYL)-2,2-DIMETHYLACETATE on Newcrom R1 HPLC column
Posted on May 16, 2018
METHYL 2-(4-BROMOPHENYL)-2,2-DIMETHYLACETATE can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method...Read more