Linoleic diethanolamide

Linoleic diethanolamide structural formula

CAS Number56863-02-6
Molecular FormulaC22H41NO3
Molecular Weight367.575
InChI KeyCKNOIIXFUKKRIC-HZJYTTRNSA-N
LogP5.32
Synonyms
  • Linoleic diethanolamide
  • (9Z,12Z)-N,N-Bis(2-hydroxyethyl)octadeca-9,12-dienamide
  • 9,12-Octadecadienamide, N,N-bis(2-hydroxyethyl)-, (9Z,12Z)-
  • 56863-02-6
  • 9,12-Octadecadienamide, N,N-bis(2-hydroxyethyl)-, (9Z,12Z)-
  • (9Z,12Z)-N,N-bis(2-hidroxietil)octadeca-9,12-dien-1-amida
  • (9Z,12Z)-N,N-Bis(2-hydroxyethyl)octadeca-9,12-dien-1-amid
  • (9Z,12Z)-N,N-Bis(2-hydroxyethyl)octadeca-9,12-dien-1-amide
  • (9Z,12Z)-N,N-bis(2-hydroxyethyl)octadeca-9,12-diene-1-amide
  • 9,12-Octadecadienamide, N,N-bis(2-hydroxyethyl)-, (Z,Z)-
  • Clindrol LT 15-73-1
  • Comperlan F
  • Cycloamide ND
  • Diethanolamine linoleamide
  • Diethanollinoleic amide
  • LINOLEAMIDE DEA
  • Linoleic acid diethanolamide
  • Linoleic acid, diethanolamine condensate
  • Linoleic diethanolamine
  • Linolic acid diethanolamide
  • Monamid 150ADY
  • Monamid 15-70W
  • N,N-Bis(2-hydroxyethyl)linoleamide
  • N,N-Bis(2-hydroxyethyl)linoleoylamide
  • OCTADECA-9,12-DIENAMIDE, N,N-BIS(2-HYDROXYETHYL)- (Z,Z)-
  • Cyclomide Din 295/S
  • EINECS 260-410-2
  • UNII-AWQ57Z0E7S

Applications:

Separation of Linoleic diethanolamide on Newcrom R1 HPLC column

May 16, 2018
Separation of Linoleic diethanolamide on Newcrom R1 HPLC column

Linoleic diethanolamide can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Linoleic diethanolamide
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.