HPLC Method for Analysis of Methotrexate on Primesep 100 by SIELC Technologies
Separation type: Liquid Chromatography Mixed-mode
Methotrexate is a chemotherapy agent and immune system suppressant. It is classified as an antimetabolite and antifolate drug. Methotrexate works by inhibiting the enzyme dihydrofolate reductase (DHFR), preventing the formation of active folate and thus interfering with DNA and RNA synthesis.
Due to its mechanism of action, methotrexate is used to treat certain types of cancer, such as leukemia, breast cancer, lung cancer, and osteosarcoma. It is also used in the treatment of autoimmune diseases, including rheumatoid arthritis and psoriasis, as it can decrease the activity of the immune system.
Like all medications, methotrexate can cause side effects and should be used under the supervision of a healthcare provider. Always consult with a healthcare professional for the most accurate and up-to-date information.
This is a chemotherapy agent and immune system suppressant. Methotrexate is an antimetabolite and antifolate drug, meaning it inhibits the metabolism of folic acid. It does this by inhibiting the enzyme dihydrofolate reductase (DHFR), preventing the formation of active folate and thus interfering with DNA and RNA synthesis. It is used to treat certain types of cancer and autoimmune diseases like rheumatoid arthritis and psoriasis.
Methotrexate retained and analyzed using a reverse-phase Primesep 100, 4.6 x 150 mm, 5 µm, 100 A column. The mobile phase for this method consists of water, acetonitrile (MeCN), and ammonium formate, which serves as a buffer. This analytical method can be monitored using UV detection at 290 nm, an Evaporative Light Scattering Detector (ELSD), or any other evaporative detection method such as Charged Aerosol Detection (CAD) or Electrospray Ionization Mass Spectrometry (ESI-MS)
LOD was determined for this combination of instrument, method, and analyte, and it can vary from one laboratory to another even when the same general type of analysis is being performed.
High Performance Liquid Chromatography (HPLC) Method for Analysis of Methotrexate
Condition
Column | Primesep 100, 4.6 x 150 mm, 5 µm, 100 A |
Mobile Phase | MeCN/H2O -50/50% |
Buffer | Ammonium formate pH 3.0 – 20 mM |
Flow Rate | 1.0 ml/min |
Detection | UV 290 nm |
Peak Retention Time | 6,12 min |
Sample concentration | 0.1 mg/ml |
Injection volume | 5 µl |
Sample diluent | H2O + NaOH |
LOD | 34 ppb |
Description
Class of Compounds | Drug, Aminopterin, Antifolates |
Analyzing Compounds | Methotrexate |
Application Column
Primesep 100
Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A