HPLC Method for Separation of Amines in Non Aqueous MP on BIST B+ Column

HPLC Method for Separation of of Amines in Non Aqueous MP on BIST B+ by SIELC Technologies

Separation type: Bridge Ion Separation Technology, or BIST™ by SIELC Technologies

HPLC Method for Separation of of Amines in Non Aqueous MP on BIST B+ Column by SIELC Technologies
HPLC Method for Separation of of Amines in Non Aqueous MP on BIST B+ by SIELC Technologies

Dopamine is a key neurotransmitter and medical stimulant used to treat low blood pressure, low heart rate, and heart attacks. m-Xylylenediamine (MXDA) is a popular curing agent used on epoxy resins. 2,4,6-Tris(dimethylaminomethyl)phenol is another amine-based curing agent used on epoxy resins. Using SIELC’s newly introduced BIST method, these 3 amines can be retained on a positively-charged anion-exchange BIST B+ column. There are two keys to this retention method: 1) a multi-charged, negative buffer, such as Sulfuric acid (H2SO4), which acts as a bridge, linking the positively-charged analytes to the positively-charged column surface and 2) a mobile phase consisting mostly of less polar organic solvent (such as IPA) to minimize the formation of a solvation layer around the charged analytes. This method uses an entirely non-aqueous mobile phase to drive BIST retention. The gradient starts with a high concentration of the less polar IPA to generate the initial BIST retention and progresses to the more polar MeOH to elute the longer-retaining amines in a reasonable time. Using this new and unique analysis method, these 3 amines can be retained and UV detected at 210 nm.

High Performance Liquid Chromatography (HPLC) Method for Analysis of of Amines in Non Aqueous MP

Condition

ColumnBIST B+, 4.6 x 150 mm, 5 µm, 100 A
Mobile PhaseGradient IPA/MeOH- 80/20% to 100% MeOH, 5 min , 5 min hold
BufferH2SO4 – 0.2%
Flow Rate1.0 ml/min
DetectionUV 210 nm
Peak Retention Time3.52 min, 6.12 min, 8.57 min

Description

Class of CompoundsAmines
Analyzing CompoundsDopamine, m-Xylylenediamine, 2,4,6-Tris(dimethylaminomethyl)phenol

Application Column

BIST B+

Column Diameter: 4.6 mm
Column Length: 150 mm
Particle Size: 5 µm
Pore Size: 100 A

Add to cart
Application Analytes:
2,4,6-Tris(dimethylaminomethyl)phenol
Dopamine
m-Xylylenediamine

Application Detection:
UV Detection
SIELC Technologies usually develops more than one method for each compound. Therefore, this particular method may not be the best available method from our portfolio for your specific application. Before you decide to implement this method in your research, please send us an email to research@sielc.com so we can ensure you get optimal results for your compound/s of interest.