DEET

DEET structural formula

CAS Number134-62-3
Molecular FormulaC12H17NO
Molecular Weight191.274
InChI KeyMMOXZBCLCQITDF-UHFFFAOYSA-N
LogP2.18
Synonyms
  • DEET
  • N,N-Diethyl-3-methylbenzamide
  • Benzamide, N,N-diethyl-3-methyl-
  • 134-62-3
  • N,N-Diethyl-m-toluamide
  • N,N-Diethyl-3-methylbenzamide
  • N,N-Diethyl-meta-toluamide
  • DEET (N,N-diethyl-meta-toluamide)
  • Benzamide, N,N-diethyl-3-methyl-
  • 3-Methyl-N,N-diethylbenzamide
  • Amincene C 140
  • Amincene C-EM
  • Amway Hour Guard
  • Bepper DET
  • Cutter Unscented
  • Delphene
  • Detamide
  • Dieltamid
  • Diethyl-m-toluamide
  • Diethyltoluamide
  • Finish MIT
  • m-Delphene
  • Metadelfene
  • Metadelphene
  • m-Toluamide, N,N-diethyl-
  • m-Toluic acid diethylamide
  • M-TOLYLSAEURE-DIAETHYLAMID
  • N,N-Diethyl-3-methylbenzoylamide
  • N,N-Diethyl-m-methylbenzamide
  • N,N-Diethyl-m-toluamid
  • N,N-Diethyl-m-tolylamide
  • N,N-dietil-m-toluamida
  • Naugatuck DET
  • NSC 33840
  • Off! Skintastic
  • Repper DET
  • Repudin-Special
  • Sawyer Control Release Formula
  • Sawyer Controlled-Release
  • Ultrathon
  • Vaseline Mosquito Repellent
  • BRN 2046711
  • Caswell No. 346
  • N,N-Diethyl-meta-toluamide
  • EINECS 205-149-7
  • EPA Pesticide Chemical Code 080301
  • MGK diethyltoluamide
  • Repper-DET
  • Diethyltoluamidum
  • Dietiltoluamida
  • UNII-FB0C1XZV4Y
  • diethyl toluamide
  • 94271-03-1

Applications:

Separation of DEET on Newcrom R1 HPLC column

February 16, 2018
Separation of DEET on Newcrom C18 HPLC column

DEET can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
DEET
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.