Amitriptyline hydrochloride

Amitriptyline hydrochloride structural formula

CAS Number549-18-8
Molecular FormulaC20H24ClN
Molecular Weight313.870
InChI KeyKFYRPLNVJVHZGT-UHFFFAOYSA-N
LogP4.52
Synonyms
  • Amitriptyline hydrochloride
  • 3-(10,11-Dihydro-5H-dibenzo[a,d][7]annulen-5-ylidene)-N,N-dimethylpropan-1-amine--hydrogen chloride (1/1)
  • 1-Propanamine, 3-(10,11-dihydro-5H-dibenzo[a,d]cyclohepten-5-ylidene)-N,N-dimethyl-, hydrochloride (1:1)
  • 549-18-8
  • Ami-Anelun
  • Amitriptyline chloride
  • Annoyltin
  • Damilen hydrochloride
  • 5-(3-Dimethylaminopropylidene)dibenzo(a,d)(1,4)cycloheptadiene hydrochloride
  • Domical
  • EINECS 208-964-6
  • Elavil hydrochloride
  • Laroxyl
  • Lentizol
  • Miketorin
  • NSC 104210
  • Proheptadien monohydrochloride
  • Rantoron
  • sk-Amitriptyline chloride
  • Tryptacap hydrochloride
  • Yamanouchi
  • Saroten
  • Oasil-M
  • Mitaptyline
  • Maxivalet
  • Larozyl
  • Kyliran
  • Daprimen
  • ADT-Zimaia
  • Tryptizol retard
  • Teperin
  • Amineurin
  • Amiplin
  • Amiprin
  • Amitrip
  • Amyline
  • Anapsique
  • Apo-Amitriptyline
  • Elatrol
  • Elatrolet
  • Etravil
  • Nornaln
  • Novoprotect
  • Novotriptyn
  • Pinsanu
  • Pinsaun
  • Saroten Retard
  • Sarotena
  • Syneudon
  • Trepiline
  • Triptizol
  • Tryptine
  • Trytomer
  • Vanatrip
  • Amitriptyline HCl
  • UNII-26LUD4JO9K
  • 8058-15-9

Applications:

Separation of Amitriptyline hydrochloride on Newcrom R1 HPLC column

May 16, 2018
Separation of Amitriptyline hydrochloride on Newcrom R1 HPLC column

Amitriptyline hydrochloride can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Amitriptyline hydrochloride
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.