Acetic acid, dianhydride with silicic acid (H4SiO4) bis(1,1-dimethylethyl) ester

Acetic acid, dianhydride with silicic acid (H4SiO4) bis(1,1-dimethylethyl) ester structural formula

CAS Number13170-23-5
Molecular FormulaC12H24O6Si
Molecular Weight292.404
InChI KeyOPARTXXEFXPWJL-UHFFFAOYSA-N
LogP2.72
Synonyms
  • Acetic acid, dianhydride with silicic acid (H4SiO4) bis(1,1-dimethylethyl) ester
  • Diacetyl di-tert-butyl orthosilicate
  • Silicic acid (H4SiO4), diacetyl bis(1,1-dimethylethyl) ester
  • 13170-23-5
  • Acetic acid dianhydride with silicic acid (H4SiO4) bis(1,1-dimethylethyl) ester
  • Acetic acid, 1,1'-dianhydride with silicic acid (H4SiO4) bis(1,1-dimethylethyl) ester
  • Acetic acid, dianhydride with (tert-BuO)2(HO)2Si
  • Acetic acid, dianhydride with silicic acid (H4SiO4) di-tert-butyl ester
  • ACETIC ACID, DIANHYDRIDE WITH SILICIC ACID BIS (1,1-DIMETHYLETHYL)ESTER
  • diacetoxidi-terc-butoxisilano
  • DIACETOXY-DI-(TERT.-BUTOXY)-SILAN
  • Diacetoxydi-t-butoxysilane
  • Diacetoxydi-tert-butoxysilan
  • Diacetoxydi-tert-butoxysilane
  • Di-tert-butoxydiacetoxysilane
  • Ditertiarybutoxydiacetoxysilane
  • Silane, di(tert-butoxy)diacetoxy-
  • SILANE, DIACETOXYDI-T-BUTOXY-
  • EINECS 236-112-3
  • UNII-D36B6TC1DM

Applications:

Separation of Acetic acid, dianhydride with silicic acid (H4SiO4) bis(1,1-dimethylethyl) ester on Newcrom R1 HPLC column

February 16, 2018
Separation of Acetic acid, dianhydride with silicic acid (H4SiO4) bis(1,1-dimethylethyl) ester on Newcrom C18 HPLC column

Acetic acid, dianhydride with silicic acid (H4SiO4) bis(1,1-dimethylethyl) ester can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Acetic acid, dianhydride with silicic acid (H4SiO4) bis(1,1-dimethylethyl) ester
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.