Riboflavin phosphate

Riboflavin phosphate structural formula

CAS Number146-17-8
Molecular FormulaC17H21N4O9P
Molecular Weight456.348
InChI KeyFVTCRASFADXXNN-SCRDCRAPSA-N
LogP-1.72
Synonyms
  • Riboflavin phosphate
  • 1-Deoxy-1-(7,8-dimethyl-2,4-dioxo-3,4-dihydrobenzo[g]pteridin-10(2H)-yl)-5-O-phosphono-D-ribitol
  • D-Ribitol, 1-deoxy-1-(3,4-dihydro-7,8-dimethyl-2,4-dioxobenzo[g]pteridin-10(2H)-yl)-, 5-(dihydrogen phosphate)
  • 146-17-8
  • 4-26-00-02554
  • Riboflavin 5'-(dihydrogen phosphate)
  • Alloxazine mononucleotide
  • Bisulase
  • Flavin mononucleotide
  • Flavine mononucleotide
  • Riboflavin 5'-monophosphate
  • Riboflavin 5'-phosphate
  • Riboflavin mononucleotide
  • Riboflavin, 5'-(dihydrogen phosphate)
  • Riboflavin-5'-(dihydrogen-phosphat)
  • riboflavina 5'-(dihidrogeno fosfato)
  • Riboflavine 5'-monophosphate
  • Riboflavine 5'-phosphate
  • Riboflavine 5-phosphate
  • Riboflavine dihydrogen phosphate
  • Riboflavine monophosphate
  • Riboflavine phosphate
  • riboflavine, (phosphate diacide)-5'
  • Vitamin B2 phosphate
  • BRN 0068086
  • EINECS 205-664-7
  • Riboflavine 5'-(dihydrogen phosphate)
  • UNII-7N464URE7E
  • FMN
  • Flanin
  • Flavol
  • Riboflavin
  • Riboflavin-5'-phosphate na
  • Riboflavine monophosphate
  • Riboflavine-5'-phosphate
  • riboflavin monophosphate
  • {[(2R,3S,4S)-5-{7,8-dimethyl-2,4-dioxo-2H,3H,4H,10H-benzo[g]pteridin-10-yl}-2,3,4-trihydroxypentyl]oxy}phosphonic acid

Applications:

Separation of Riboflavin phosphate on Newcrom R1 HPLC column

May 16, 2018
Separation of Riboflavin phosphate on Newcrom R1 HPLC column

Riboflavin phosphate can be analyzed by this reverse phase (RP) HPLC method with simple conditions. The mobile phase contains an acetonitrile (MeCN), water, and phosphoric acid. For Mass-Spec (MS) compatible applications the phosphoric acid needs to be replaced with formic acid. Smaller 3 µm particles columns available for fast UPLC applications. This liquid chromatography method is scalable and can be used for isolation impurities in preparative separation. It also suitable for pharmacokinetics.

Application Column

Newcrom R1

The Newcrom columns are a family of reverse-phase-based columns. Newcrom A, AH, B, and BH are all mixed-mode columns with either positive or negative ion-pairing groups attached to either short (25 Å) or long (100 Å) ligand chains. Newcrom R1 is a special reverse-phase column with low silanol activity.

Select options
Application Analytes:
Riboflavin phosphate
The result was obtained by a proprietary SIELC algorithm. It may deviate from the actual experimental data. The experimental data are available upon request. Contact us by e-mail: support@sielc.com or by phone: 847-229-2629.